Standard of Glass Products – Insulated Glass

The differences between this standard and GB/T 11944-1989 and GB/T 7020-1986 are:

•  Redefining of insulated glass. It includes the glue-bar insulated glass.

•  The general dimension and max. size of insulated glass. It consults BS 5713:1979 rules.

•  The size tolerance insulated glass consults rules JIS R3209-1998.

•  The seal ability of insulated glass adds more technical requirements to 5mm + 9mm + 5mm .

•  It prescribes the contacting time of drosometer and glass in the dew point test by consulting ASTM E546-1988 and JIS R3209-1998.

•  It adds environmental conditions requirements to seal ability test, dew point test, climate cycle wear test.

•  It adds requirements of mislocation to raw glass and creep of glue-bar in ultraviolet radiation radiazation resistant test. There is no requirement on environmental conditions.

•  Do the climate cycle wear test and high temperature and humidity wear test separately.

•  Range

This standard prescribes the dimension, technical requiremwnts, inspection method, inspection rules, package, marks,transporting and storage of insulated glass.

This standard is suitable for producing insulated glass for architecture and refrigeration.

•  Canonical Application Documents

The items included in the below standard becomes the items of this standard by referring in this standard. The referred documents with date, whose modifying list (excluding errata content) or revised edition are not suitable for this standard. But, encourage whether every study coming to an agreement according to this standard can use this latest edition. The referred documents without date, whose latest edition is suitable for this standard.

GB/T 1216 Outside micrometer (neq ISO 3611)

GB 9962 Laminated glass

GB/T 9963 Tempered glass

GB/T 11614 Float glass

GB 17841 Tempered glass and semi-tempered glass for screen wall

JC/T 486 Insulated glass with stretched seal

•  Terms and Definition

Insulated glass

Two or more glass sheets are insulated equably by effective support and sealed airproofly, thus between the glass sheets, it is full of dry air.

 
 